Dawn Namibia
  • Home
  • About Us
  • Products
    • Water Dispensers
    • Reverse Osmosis
      • RO Package Plant
      • RO Industrial
      • RO Home Use
    • Turnkey Containerized RO Plants
    • Water Measuring Equipment
      • TDS Testers
      • PH Meter
    • Ice Makers
      • Ice Makers
        • Ice Cube Vending Machines
    • Membranes
      • Dawn Membranes
      • E-MEM Membranes
      • Vontron Membranes
      • RO Membrane Element
    • Pumps
    • Fittings
    • Filters
      • Filter Media
      • Filter Housing
      • Filter Cartriges
    • Cooling Towers
    • Plants
    • FRP Vessels
    • Filter & Softener Valves
    • Storage Tanks
    • Oxygen
  • Jobs Done
  • Business Opportunities
    • Water Shop Setup
    • Water Filling Line
    • Bottle Blowing Machine
    • Water Bottling Plant
    • Water Purification
    • Water Bar
  • FAQ
  • Contact Us

RO Industrial

100L/H RO SYSTEM-800 GPD
100 L/H RO system-800 GPD
(N$ 26 950.00 VAT EX)

100 L/H RO SYSTEM-800 GPD (N$ 26 950.00 VAT EX)

100L/H RO SYSTEM-800 GPD
 Specification
  • Production Capacity: 800GPD / 100LPH @ 25°C
  • Salt Rejection: 96-98%
  • Recovery Rate: 50-75%
  • Connection: 3/8”Feed, 1/2”Permeate, 1/2”Concentrate
Components
  • RO Membrane:5”x40”
  • Membrane Housing: SS304 body + ABS end caps – 2054 x 1pc
  • Pump: Italian Rotary Vane Pump 400LPH@12Bar + 1/2HP Taiwan Motor
  • Frame: Electro-Plated SS304
  • Pre-Filter: (20” KF Housing + PP Cartridge 5um) x 2 , sets Solenoid Valve x 2 , Low Pressure Switch x 1 , Concentrate Recycling Valve x 1
Control Panel Components
  • RO controller: Pre-programmed RO working procedures + permeate TDS monitor
  • Pressure Gauges x 2: Filter Feed + RO Feed
  • Flow Meters x 2: RO Permeate + RO Concentrate Pressure Regular: SS316
  • Main Power Switch x 1

 

Application
  • Water Store
  • Spot Free Car Wash
  • Laboratory Electro-Plating Factory
  • Small Bottle Water Filling Plant
  • Other Manufacturing Facilities
  • Brackish Water Desalination (TDS600-1500ppm)
Close
1600 GPD RO SYSTEM
200 L/H RO system-1600 GPD
(N$ 33 248.25 VAT EX)

200 L/H RO SYSTEM-1600 GPD (N$ 33 248.25 VAT EX)

1600 GPD RO SYSTEM 
Specification
  • Production Capacity: 1600GPD / 200LPH @ 25°C
  • Salt Rejection: 96-98% Recovery
  • Rate: 50-75%
  • Connection: 3/8”Feed, 1/2”Permeate, 1/2”Concentrate
Components
  • 2xRO Membrane:5”x40”
  • Membrane Housing: SS304 body + ABS end caps – 2054 x 2pc
  • Pump: Italian Rotary Vane Pump 400LPH@12Bar + 1/2HP Taiwan Motor
  • Frame: Electro-Plated SS304
  • Pre-Filter: (20” KF Housing + PP Cartridge 5um) x 2 sets
  • Solenoid Valve x 2
  • Low Pressure Switch x 1
  • Concentrate Recycling Valve x 1
 Control Panel Components
  • Pre-programmed RO working procedures + permeate TDS monitor
  • Pressure Gauges x 2: Filter Feed + RO Feed
  • Flow Meters x 2: RO Permeate + RO Concentrate
  • Pressure Regular: SS316
  • Main Power Switch x 1
Application
  • Water Store
  • Spot Free Car Wash
  • Laboratory Electro-Plating Factory
  • Small Bottle Water Filling Plant
  • Other Manufacturing Facilities
  • Brackish Water Desalination (TDS600-1500ppm)
Close
250L/H RO SYSTEM-2000 GPD
250L/H RO system 2000 GPD
(N$ 41 998.25 VAT EX)
250L/H RO SYSTEM-2000 GPD
 Description

Puritech’s compact commercial reverse osmosis system is a durable  piece of equipment which, with proper care and maintenance will last for many years. RD series systems are part of a family of reverse osmosis units designed for operation with fresh and brackish feedwaters having TDS values below 2,000ppm. Models are available with permeate outputs ofbetween 300 and 700 litresfhr as shown in the specifications tables.

 
Specifications
  • Capacity (GDP/LPH): 2000/300
  • Working Pressure (PSI/BAR): 150-200/10-14
  • Pre-Filtration: (20″ Filter Housing x2) + (20″ PP Cartridge 5u + 1u)
  • Booster Pump: Rotary Van Pump Motor (1HP)
Membrane
  • Material: F.C with FRP outer wrap
  • Size + Unit: 4040 x 1
Membrane Housing
  • Material: High Pressure TRP end port type
  • Size x Unit: 4040 x 1
  • Flow Meters: Permeate/Concentrate
  • Pressure Gauges: Feed water pressure/Booster pump outlet pressure gauge
  • Water Quality Indicator:D.S meter with LCD
  • Electrical Controls: Micro-computer control, overload breakers, LED indicators
  • Frame: Electro-polished stainless steel 304
  • Weight: 64KG
 Feed Water Parameters
  • Turbity (SD): <5
  • D.S.: <2000 ppm=”” br=””>Temperature: +5 to 40 oC
  • Free Chlorine: 0 ppm pH: 3-11
  • Iron: <0.01 ppm=”” p=””>
Close
500-L/H RO SYSTEM
500-L/H RO system-4000 GPD
(N$ 69 998.25 VAT EX)

500-L/H RO SYSTEM-4000 GPD (N$ 69 998.25 VAT EX)

500-L/H RO SYSTEM

Description

Dawn Namibia (Pty) Ltd  compact commercial reverse osmosis system is a durable  piece of equipment which, with proper care and maintenance will last for many years. RD series systems are part of a family of reverse osmosis units designed for operation with fresh and brackish feed waters having TDS values below 2,000ppm. Models are available with permeate outputs of between 4000 Gpd and 700 lph as shown in the specifications tables.

 Specifications
  • Capacity (GDP/LPH): 4000/700
  • Working Pressure (PSI/BAR): 150-200/10-14
  • Pre-Filtration: (20″ Filter Housing x2) + (20″ PP Cartridge 5u + 1u)
  • Booster Pump: Multi-staged Centrifugal Pump (3HP)
Membrane
  • Material:F.C with FRP outer wrap Size + Unit: 4040 x 2
  • Membrane Housing Material: High Pressure TRP end port type Size x Unit: 4040 x 2
  • Flow Meters: Permeate/Concentrate
  • Pressure Gauges: Feed water pressure/Booster pump outlet pressure gauge
  • Water Quality Indicator:D.S meter with LCD
  • Electrical Controls: Micro-computer control, overload breakers, LED indicators
  • Frame: Electro-polished stainless steel 304
  • Weight: 107KG
Feed Water Parameters
  • Turbity (SD): <5
  • D.S.: <2000 ppm=”” br=””>
  • Temperature: +5 to 40 oC
  • Free Chlorine: 0 ppm
  • pH: 3-11
  • Iron: <0.01 ppm=”” –2000–=””>
Close
500L/H RO SYSTEM - 4000 GPD
500L/H RO system -4000 GPD
(N$ 69 998.25 VAT EX)

500L/H RO SYSTEM -4000 GPD (N$ 69 9998.25 VAT EX)

500L/H RO SYSTEM - 4000 GPD

Description

Dawn Namibia (Pty) Ltd compact commercial reverse osmosis system is a durable  piece of equipment which, with proper care and maintenance will last for many years. RD series systems are part of a family of reverse osmosis units designed for operation with fresh and brackish feed waters having TDS values below 2,000ppm. Models are available with permeate outputs of between 4000 Gpd and 700 lph as shown in the specifications tables.

 Specifications
  • Capacity (GDP/LPH): 4000/700
  • Working Pressure (PSI/BAR): 150-200/10-14
  • Pre-Filtration: (20″ Filter Housing x2) + (20″ PP Cartridge 5u + 1u)
  • Booster Pump: Multi-staged Centritugal Pump (3HP)
 Membrane
  • Material: F.C with FRP outer wrap Size + Unit: 4040 x 2
  • Membrane Housing Material: High Pressure TRP end port type Size x Unit: 4040 x 2
  • Flow Meters: Permeate/Concentrate
  • Pressure Gauges: Feed water pressure/Booster pump outlet pressure gauge
  • Water Quality Indicator:D.S meter with LCD
  • Electrical Controls: Micro-computer control, overload breakers, LED indicators
  • Frame: Electro-polished stainless steel 304
  • Weight: 107KG
Feed Water Parameters
  • Turbity (SD): <5
  • D.S.: <2000 ppm=”” br=””>
  • Temperature: +5 to 40 oC
  • Free Chlorine: 0 ppm
  • pH: 3-11
  • Iron: <0.01 ppm=”” –2000–=””>
Close
1000 L/H RO SYSTEM-6000 GPD
1000 L/H RO system-6000 GPD
(N$ 113 750.00 VAT EX)

1000 L/H RO SYSTEM-6000 GPD (N$ 113 750.00 VAT EX)

1000 L/H RO SYSTEM-6000 GPD

Description
  • Sediment Filter: 1 Micron Sediment Filter that removes sediments and protects the system.
  • High Pressure Pump: 1HP Motor Vertical Multi-Stage Pump with flow rate of 1080 Liters/H. High quality stainless steel Shimgi Pump for long-life usage.
  • RO Membrane: One of the industry’s leading brackish water RO elements – Vontron-4040.
  • Membrane Housing: 4″ x 40″ Stainless Steel Housing with 300PSI maximum operating pressure.
  • Pressure Gauges: Glycerin Filled Gauges for monitoring the system’s operating pressure and per liter operating pressures.
  • Low Pressure Switch: Safety device to protect the pump from running dry when there is insufficient water feed pressure.
  • Solenoid Valves: To assist with the on/off functionality of the system and automatic membrane flush.
  • Flow Meters: One Product and One Waste Flow Meters – Enables operator to actuary adjust product to waste ratio and monitor system’s performance.
  • Regulator Valve: One Stainless Steel ANSI 316 Needle Valve – regulates the product to waste ratio (system’s recovery).
  • Micro-Computer Controller: A specialized controller designed by Puritech for commercial systems with automatic controls and TDS monitors.
 Optional Features

Stainless Steel Components: ANSI 304 and 316 can be used with solenoid valves and pumps for brackish water treatment.

  • Concentrate Re-Circulation
  • Automatic Pre-treatment Systems
  • Chemical Dosing Pumps
 Specification
  • Capacity: 6000 GPD
  • RO Membrane: 4 pcs
  • RO Pump: 1HP
  • Voltage/Hertz: 110V or 220V / 50Hz or 60Hz / Single phase or three phase
  • Pipe Size: 3/4″ Feed, 1/2″ Permeate, 1/2″ Concentrate, 1/2″ Flush (BSP thread)
Operating Parameters
  • Operating Pressure: 180 PSI | Max. Feed TDS | 1000 ppm
  • Normal Salt Rejection: 99% | Max. Feed Hardness | 15 ppm
  • Minimum Salt Rejection: 96% | Feed pH Range | 3.0 – 10.0 ppm
  • Operating Temperature: 20 oC – 45 oC | Free Residual Chlorine | 0.1 ppm
  • Minimum Feed Pressure:5Kg | Recovery Rate | 60% – 75%
Close
1
10000 LPH RO System
(VAT EX)

10000 LPH RO System

PLEASE NOTE!

When you consider purchasing this system, you need to know the following information as it is very important. This system requires a pretreatment setup for it to perform like it was designed to. Below, the sketch shows a basic pretreatment setup with the reverse osmosis system.

typical-ro-system-setup-159-1024x288

The above pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the water analysis report from a lab.

A water analysis report is very important as it determines the pretreatment setup. As you can see on the sketch above, the pretreatment consists of a Sand/Glass Filter, Carbon Filter, and Antiscalant Dosing system.

Pretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.
Chlorine Dosing System
Ultrafiltration System
Dmi-65 Iron Removal Media Filter System
Ozone Generator
Flocculant System

Once all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.

Training can also be offered to the guys you want to be the ones installing your setup instead of our technicians.

THE INDUSTRIAL REVERSE OSMOSIS SYSTEM
RO membrane water purifier uses semi-permeable spiral wound membranes to separate and remove dissolved solids, organic, sub-micron colloidal matter, and bacteria from water. Water permeates the minute pores of the membrane and is delivered as purified water. Impurities in the water are concentrated in the reject stream and flushed to drain. Reverse osmosis is capable of removing 90-99% of total dissolved solids (TDS), 99% of organic, including pyrogens, and 99% of all bacteria in the feed water. Reverse osmosis RO machine is very dense and has a very high removal rate for viruses, ions, phage, and bacteria, at least above 3log (removal rate >99.9%).

Close
2
2000 LPH RO System
(VAT EX)

2000 LPH RO System

PLEASE NOTE!

When you consider purchasing this system, you need to know the following information as it is very important.
This system requires a pretreatment setup for it to perform like it was designed to.

Below, the sketch shows a basic pretreatment setup with the reverse osmosis system.

typical-ro-system-setup-159-1024x288

The above pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the water analysis report from a lab.

A water analysis report is very important as it determines the pretreatment setup. As you can see on the sketch above, the pretreatment consists of a Sand/Glass Filter, Carbon Filter, and Antiscalant Dosing system.

Pretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.
Chlorine Dosing System
Ultrafiltration System
Dmi-65 Iron Removal Media Filter System
Ozone Generator
Flocculant System

Once all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.

Training can also be offered to the guys you want to be the ones installing your setup instead of our technicians.

THE INDUSTRIAL REVERSE OSMOSIS SYSTEM
RO membrane water purifier uses semi-permeable spiral wound membranes to separate and remove dissolved solids, organic, sub-micron colloidal matter, and bacteria from water. Water permeates the minute pores of the membrane and is delivered as purified water. Impurities in the water are concentrated in the reject stream and flushed to drain. Reverse osmosis is capable of removing 90-99% of total dissolved solids (TDS), 99% of organic, including pyrogens, and 99% of all bacteria in the feed water. Reverse osmosis RO machine is very dense and has a very high removal rate for viruses, ions, phage, and bacteria, at least above 3log (removal rate >99.9%).

Close
3
2000GPD RO System
(VAT EX)

2000GPD RO System

PLEASE NOTE!

When you consider purchasing this system, you need to know the following information as it is very important.
This system requires a pretreatment setup for it to perform like it was designed to.

Below, the sketch shows a basic pretreatment setup with the reverse osmosis system.

typical-ro-system-setup-159-1024x288

The above pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the water analysis report from a lab.

A water analysis report is very important as it determines the pretreatment setup. As you can see on the sketch above, the pretreatment consists of a Sand/Glass Filter, Carbon Filter, and Antiscalant Dosing system.

Pretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.
Chlorine Dosing System
Ultrafiltration System
Dmi-65 Iron Removal Media Filter System
Ozone Generator
Flocculant System

Once all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.

Training can also be offered to the guys you want to be the ones installing your setup instead of our technicians.

THE INDUSTRIAL REVERSE OSMOSIS SYSTEM
RO membrane water purifier uses semi-permeable spiral wound membranes to separate and remove dissolved solids, organic, sub-micron colloidal matter, and bacteria from water. Water permeates the minute pores of the membrane and is delivered as purified water. Impurities in the water are concentrated in the reject stream and flushed to drain. Reverse osmosis is capable of removing 90-99% of total dissolved solids (TDS), 99% of organic, including pyrogens, and 99% of all bacteria in the feed water. Reverse osmosis RO machine is very dense and has a very high removal rate for viruses, ions, phage, and bacteria, at least above 3log (removal rate >99.9%).

2000 GDP RO System
PURITECH compact Industrial reverse osmosis system is a durable piece of equipment that, with proper care and maintenance will last for many years. The systems are part of a family of reverse osmosis units designed for operation with fresh and brackish feedwaters having TDS values below 1,500ppm. Models are available with permeate outputs of between 150 and 1,000 litres/hr as shown in the specifications.

The rack has been changed from the original 38cm*38cm to 25cm*25cm. Now the dimension of the RO main host can reach 50cmx60cmx130cm, which is 40% smaller than the water treatment system on the market. We also have more compact spacers for parts, components, and smaller racks, which now have less material. Because we redesigned the frame and component construction, saving materials, and lower cost than conventional products. This RO water plant is especially suitable for customers who are sensitive to the product price and freight and also wants to develop new markets with a lower investment of costs.

Close
4
2000GPD RO System
(VAT EX)

2000GPD RO System

PLEASE NOTE!

When you consider purchasing this system, you need to know the following information as it is very important.
This system requires a pretreatment setup for it to perform like it was designed to.

Below, the sketch shows a basic pretreatment setup with the reverse osmosis system.

typical-ro-system-setup-159-1024x288

The above pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the water analysis report from a lab.

A water analysis report is very important as it determines the pretreatment setup. As you can see on the sketch above, the pretreatment consists of a Sand/Glass Filter, Carbon Filter, and Antiscalant Dosing system.

Pretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.
Chlorine Dosing System
Ultrafiltration System
Dmi-65 Iron Removal Media Filter System
Ozone Generator
Flocculant System

Once all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.

Training can also be offered to the guys you want to be the ones installing your setup instead of our technicians.

THE INDUSTRIAL REVERSE OSMOSIS SYSTEM
RO membrane water purifier uses semi-permeable spiral wound membranes to separate and remove dissolved solids, organic, sub-micron colloidal matter, and bacteria from water. Water permeates the minute pores of the membrane and is delivered as purified water. Impurities in the water are concentrated in the reject stream and flushed to drain. Reverse osmosis is capable of removing 90-99% of total dissolved solids (TDS), 99% of organic, including pyrogens, and 99% of all bacteria in the feed water. Reverse osmosis RO machine is very dense and has a very high removal rate for viruses, ions, phage, and bacteria, at least above 3log (removal rate >99.9%).

2000 GDP RO System
PURITECH compact Industrial reverse osmosis system is a durable piece of equipment that, with proper care and maintenance will last for many years. The systems are part of a family of reverse osmosis units designed for operation with fresh and brackish feedwaters having TDS values below 1,500ppm. Models are available with permeate outputs of between 150 and 1,000 litres/hr as shown in the specifications.

The rack has been changed from the original 38cm*38cm to 25cm*25cm. Now the dimension of the RO main host can reach 50cmx60cmx130cm, which is 40% smaller than the water treatment system on the market. We also have more compact spacers for parts, components, and smaller racks, which now have less material. Because we redesigned the frame and component construction, saving materials, and lower cost than conventional products. This RO water plant is especially suitable for customers who are sensitive to the product price and freight and also wants to develop new markets with a lower investment of costs.

Close
5
3000 LPH RO System
(VAT EX)

3000 LPH RO System

PLEASE NOTE!

When you consider purchasing this system, you need to know the following information as it is very important.
This system requires a pretreatment setup for it to perform like it was designed to.

Below, the sketch shows a basic pretreatment setup with the reverse osmosis system.

typical-ro-system-setup-159-1024x288

The above pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the water analysis report from a lab.

A water analysis report is very important as it determines the pretreatment setup. As you can see on the sketch above, the pretreatment consists of a Sand/Glass Filter, Carbon Filter, and Antiscalant Dosing system.

Pretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.
Chlorine Dosing System
Ultrafiltration System
Dmi-65 Iron Removal Media Filter System
Ozone Generator
Flocculant System

Once all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.

Training can also be offered to the guys you want to be the ones installing your setup instead of our technicians.

FEATURES
Sediment Filter: 5 Micron Sediment Filter that removes sediments and protects the system.
High-Pressure Pump: 1HP Motor Vertical Multi-Stage Pump with a flow rate of 1080 Liters/H.
High-quality stainless steel Shimge Pump for long-life usage.
RO Membrane: One of the industry’s leading brackish water RO elements – Vontron-8040.
Membrane Housing: 8.0″ x 40″ Ceramic Housing with 300PSI maximum operating pressure.
Pressure Gauges: Glycerin Filled Gauges for monitoring the system’s operating pressure and per liter operating pressures.
Low-Pressure Switch: Safety device to protect the pump from running dry when there is insufficient water feed pressure.
Flow Meters: One Product and One Waste Flow Meters – Enables the operator to actually adjust the product to waste ratio and monitor the system’s performance.
Regulator Valve: One Stainless Steel ANSI 316 Needle Valve – regulates the product to waste ratio (system’s recovery).
Micro-Computer Controller: A specialized controller designed by Purltech for commercial systems with automatic controls and TDS monitors.

SPECIFICATION
Capacity: 18000 GPD
RO Membrane: 3 pcs
RO Pump: 3HP
Voltage/Hertz: 110V or 220V / 50Hz or 60Hz / Single phase or three phase Pipe Size: 3/4″ Feed, 1/2″ Permeate, 1/2″ Concentrate, 1/2″ Flush (BSP thread)

Close
6
4000 LPH RO System
(VAT EX)

4000 GPD RO System

PLEASE NOTE!

When you consider purchasing this system, you need to know the following information as it is very important.
This system requires a pretreatment setup for it to perform like it was designed to.

Below, the sketch shows a basic pretreatment setup with the reverse osmosis system.

typical-ro-system-setup-159-1024x288

The above pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the water analysis report from a lab.

A water analysis report is very important as it determines the pretreatment setup. As you can see on the sketch above, the pretreatment consists of a Sand/Glass Filter, Carbon Filter, and Antiscalant Dosing system.

Pretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.
Chlorine Dosing System
Ultrafiltration System
Dmi-65 Iron Removal Media Filter System
Ozone Generator
Flocculant System

Once all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.

Training can also be offered to the guys you want to be the ones installing your setup instead of our technicians.

Close
  • 1
  • 2

At Dawn water solutions (Pty) Ltd, we measure ourselves by the quality of the company we keep.

And when we say “keep” we mean long-term partnerships that Produce results.

“Rest assured, where you find our name, you will find other names you know and respect”

Contact Details

Palnic Square, Cnr Nickel and Titanium streets, Prosperita
C: +264 81 649 4522
E: info@dawnnamibia.com / sales@dawnnamibia.com

Follow Us On Facebook

Dawn Namibia Website By iMarketing Consultants